• Home
  • Products
    • Joint
      • TTA RAPID­®
      • RAPID Patella Luxation
      • TPLO
      • TPLO and Patella Luxation
      • CBLO
      • CCWO
    • Osteosynthesis
      • LeiLOX Locking Fracture Systems
      • Standard Osteosynthesis Plates
      • LeiCOM Cannulated Compression Screws
    • LeiLa Bone Substitutes
      • Hydroxyapatite Bone Paste
      • Bone Graft Granules
    • 3D HIP
      • 3D HIP Order Form
    • Neuro and Spinal Surgery
      • LeiCAGE Intervertebral Titanium Cages
      • LeiPED Pedicle Screw System
        • Lumbosacral Fixation
      • LeiMESH Cuttable Mesh Plate System
      • C-LOX Intervertebral Implants
    • Arthroscopy
      • Arthroscopy Small Animal
      • Arthroscopy Equine
    • Surgical Instruments
      • Sulcoplasty
      • Micro Surgery
    • Others
      • S.O.S. Screw Extraction Set
      • K-Wires and Cerclage
  • Shop
  • Academy
    • All Workshops
    • Registration
    • Lecturers
    • Workshops by Category
      • TTA RAPID® & Patella Luxation
      • TPLO
      • CBLO
      • CCWO
      • CrCL Ruptures in Small Animals
      • Fracture Management
      • Headless Compression Screws
      • 3D HIP
      • Arthroscopy
      • Spinal Surgery
    • Online CE Courses
      • TTA RAPID Online Course
      • Tiny TTA RAPID Online Course
      • RAPID LUXATION Online Course
    • Webinars
  • Tips
  • Contact
  • Jobs
  • Events
  • News
  • Newsletter
  • English
  • German
  • Home
  • Products
    • Joint
      • TTA RAPID­®
      • RAPID Patella Luxation
      • TPLO
      • TPLO and Patella Luxation
      • CBLO
      • CCWO
    • Osteosynthesis
      • LeiLOX Locking Fracture Systems
      • Standard Osteosynthesis Plates
      • LeiCOM Cannulated Compression Screws
    • LeiLa Bone Substitutes
      • Hydroxyapatite Bone Paste
      • Bone Graft Granules
    • 3D HIP
      • 3D HIP Order Form
    • Neuro and Spinal Surgery
      • LeiCAGE Intervertebral Titanium Cages
      • LeiPED Pedicle Screw System
        • Lumbosacral Fixation
      • LeiMESH Cuttable Mesh Plate System
      • C-LOX Intervertebral Implants
    • Arthroscopy
      • Arthroscopy Small Animal
      • Arthroscopy Equine
    • Surgical Instruments
      • Sulcoplasty
      • Micro Surgery
    • Others
      • S.O.S. Screw Extraction Set
      • K-Wires and Cerclage
  • Shop
  • Academy
    • All Workshops
    • Registration
    • Lecturers
    • Workshops by Category
      • TTA RAPID® & Patella Luxation
      • TPLO
      • CBLO
      • CCWO
      • CrCL Ruptures in Small Animals
      • Fracture Management
      • Headless Compression Screws
      • 3D HIP
      • Arthroscopy
      • Spinal Surgery
    • Online CE Courses
      • TTA RAPID Online Course
      • Tiny TTA RAPID Online Course
      • RAPID LUXATION Online Course
    • Webinars
  • Tips
  • Contact
  • Jobs
  • Events
  • News
  • Newsletter
  • English
  • German

Rita Leibinger Medical × Evidensia Ravensburg | More than 15 Years of Trusted PartnershipGeneral news and information

  • Home
  • /
  • Archives: General

General

Rita Leibinger Medical × Evidensia Ravensburg | More than 15 Years of Trusted Partnership

Some partnerships are not built overnight. They develop over many years through shared experience, ...

Read More

Case Studies & Success Stories, General

Skeeter’s Road to Recovery: Successful Repair of a Radius-Ulna Fracture with LeiLOX 2.0 mm Titanium Plate

Case Overview In November 2025, Skeeter, a 14-week-old Doodle puppy weighing 9.4 lbs (4.3 ...

Read More

Case Studies & Success Stories, General

Pioneering Small Patient Orthopedics with the 1.5 mm LeiLOX TPLO Swing Titanium Plate

Pioneering Small Patient Orthopedics with the 1.5 mm LeiLOX TPLO Swing Titanium Plate Case ...

Read More

Case Studies & Success Stories, General

A Rescue Puppy´s Recovery Story: Lateral Humeral Condylar Fractur Repair Using LeiCOM Compression Screws

Case Overview What began as a routine transport for 15 rescue animals turned into ...

Read More

Case Studies & Success Stories, General

Bicycle Trauma Defeated: Proving the Power of the New 1.0 mm LeiLOX Plate in Complex Canine Fractures

Case Overview In April 2025, a 3-year-old, 5.6 kg mixed breed dog suffered a ...

Read More

Case Studies & Success Stories, General

This is why they named the cat LeiLOX

Our client Dr. Sonntag recently wrote us an email with the subject: Here’s why ...

Read More

Case Studies & Success Stories, General

Tiny Plates, Big Impact: TPLO for Small Dogs

Expanding TPLO Beyond Big Breeds For years, TPLO surgery was largely reserved for medium ...

Read More

Case Studies & Success Stories, General

Innovative 3D HIP Surgery on One of the Tiniest Canine Patients so far

Case Overview In July 2025, a tiny Shiba Inu weighing only 5.8 kg underwent ...

Read More

Case Studies & Success Stories, General

Saving the Wild: Caracal’s Femur Fixed with LeiLOX Plate

Case Overview In April 2025, a stunning caracal suffering from a femur fracture began ...

Read More

Case Studies & Success Stories, General

Complex Pelvic Fracture in a Cat – Stabilized with LeiLOX Implants

Case Overview This feline patient presented with a severe pelvic trauma following high-impact trauma. ...

Read More
Load More

Contact

Am Lippach 14, Muehlheim, BW, 78570, Germany

+49 7463 99 291 0

info@leibinger-medical.com

Social

  • Privacy
  • Terms of service
  • Imprint
  • Downloads
  • Jobs

Copyright 2026 Rita Leibinger GmbH & Co. KG, all rights reserved.

  • English
  • German