fbpx
CCWO Advantage
LeiLOX CCWO
Ideal for Steep TPAs and Juvenile Dogs

CCWO utilizes linear cuts, and specifically designed to avoid the growth plates in juvenile patients. It excels in addressing steep tibial plateau angles, providing a solution where other surgical methods may be less effective or too challenging.

Multiaxial Locking
LeiLOX CCWO
Multiaxial Locking

Its multiaxial locking capability enables you to angle the screws
away from vital structures.

Anatomically shaped plates
LeiLOX CCWO
Anatomically shaped plates

Contoured to match the natural shape of the bone to facilitate optimal positioning with ease.

Interchangeable Screws
LeiLOX CCWO
Interchangeable Screws

Versatility meets efficiency with the LeiLOX CCWO, TPLO, & CBLO Systems, offering interchangeable compatibility across screw sizes and plates.

Titanium for Best Biocompatibility
LeiLOX CCWO
Titanium for Best Biocompatibilty

Its excellent biocompatibility minimizes adverse immune reactions when implanted into the body, promoting better integration with surrounding tissues.

previous arrow
next arrow

Tailored for Steep Tibial plateau angles

Precision Approach to CCL Injuries

Cranial Closing Wedge Osteotomy (CCWO) is a biomechanical procedure that involves reshaping the proximal tibia (near the knee joint) by removing a wedge-shaped section of bone. This changes the tibial plateau angle (TPA) to neutralize the abnormal forward motion of the tibia, known as tibial thrust, which occurs during weight-bearing in dogs with cranial cruciate ligament (CCL) injuries.


While other surgical options like Tibial Plateau Leveling Osteotomy (TPLO) and Tibial Tuberosity Advancement (TTA) are commonly used, CCWO offers unique advantages in specific scenarios:

  • Ideal for dogs with extremely steep tibial plateau angles.
  • Suitable for patients where other procedures might not adequately address anatomical variations.
  • Provides a robust and long-lasting solution for stifle stabilization.

The CCWO Advantage: Precision for Steep TPAs and Juvenile Patients

CCWO is a straightforward technique that uses precise linear cuts, making it an ideal option for juvenile patients as it avoids the growth plates, ensuring proper bone development. This method is particularly effective for dogs with steep tibial plateau angles, providing a reliable solution where other surgical techniques may struggle. By realigning the tibia and reducing tibial thrust, CCWO restores stability to the stifle joint, offering a long-lasting outcome even in challenging cases. Its simplicity and precision make it a versatile choice for a variety of patients.

Anatomically Shaped Limited Contact Dynamic Compression Plates

The LeiLOX CCWO plates are precisely contoured to match the bone's natural shape, ensuring optimal placement and enhanced stability. Featuring limited contact dynamic compression, the plate minimizes vascular damage to the bone, promoting improved blood flow and supporting faster healing.

Multiaxial Locking for Precision and Flexibility in Fixation

The screws are designed to be locked at a 90° angle with up to a 12° deviation in any direction, offering exceptional flexibility in positioning. This capability allows screws to be angled strategically away from vital structures, reducing the risk of injury to surrounding tissues. Additionally, the robust LeiStar screw head securely locks into the plate, providing a firm and stable fixation, ensuring the plate's integrity and the success of the surgical procedure.

Interchangeable Screws: Flexibility and cost-efficiency

Versatility meets efficiency with the LeiLOX CCWO System, offering interchangeable compatibility across screw sizes and plates within the 2.7/3.5mm and 2.0/2.4mm CCWO, CBLO, and TPLO Titanium Systems. Featuring identical screw heads, the screws offers unprecedented flexibility in implant selection (within their respective systems), tailored to the unique needs of each patient. Moreover, this interchangeability streamlines inventory management, reducing costs and optimizing resource utilization.

Titanium for Optimal Biocompatibility

LeiLOX CCWO implants are made from medical-grade titanium, offering several key benefits: exceptional biocompatibility, ensuring optimal tolerance by the body and minimizing the risk of adverse reactions; superior strength and durability, providing reliable support during the healing process and long-term stability; and outstanding corrosion resistance, making them ideal for long-term implantation while maintaining their integrity over time.

Learn the CCWO Technique

in one of our Workshops

2025

CCWO 2-Day Intensive Course - 4. April 2025 - 5. April 2025 in Germany
Cranial Closing Wedge Surgery - 6. May 2025 in United Kingdom

Questions?

You may call us at +49 7463 992 910 (Headquarters in Germany) or email us directly by clicking on the button below. OR fill out the form at the right and send.

LeiLOX CCWO Titanium

By submitting this form, you agree that your data will be stored by Rita Leibinger GmbH & Co. KG to process your request and/or respond to your message. You also hereby confirm that you have read our privacy policy and accept it.